SHIPS VIA FREIGHT (charges apply)
Description
Standard low temperature forced convection incubators applicable for low temperature tests and environmental tests. Models available in 155V or 220V.
Features
Operation and functions
- High accuracy temperature control and temperature distribution
- Inner glass door keeps temperature stable during sample observation
- Designed with a large dual glass door and inner door that forms a triplex glass door for improved heat retention (IN604W/804W)
- Interior light for better sample visibility (IN604W/804W)
- Optional slide shaker table available to put in and take out samples easily (IN604W/804W)
Specifications
System | Forced air convection |
Operating Temperature Range | -10°C~+50°C |
Temperature Adjustment Accuracy | ±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation) |
Temp. Distribution Accuracy | ±1.0°C (refrigerator in continuous operation at 37°C) |
Max. Temp. Reaching Time | 20~50°C ~20min |
Minimum Temp. Reaching Time | 20~-10°C ~ 45min |
Interior Material | Stainless steel |
Exterior Material | Chrome free electronic galvanized plated steel plate chemical proof baking finish |
Observation Window | --- |
Heat Insulation Material | Styrene foam |
Refrigerator | Air-cooled fully closed compressor 250W |
Refrigerator Medium | R134A |
Defrosting Mechanism | Manual ON / Auto OFF, Timer operation, Cycle operation |
Blower Fan | Axial fan |
Heater | Iron-chrome wire heater: 550W |
Sensor | Platinum resistance temperature detector: Pt100Ω (temp. controller), K-thermocouple (overheat prevention device) |
Cable Port (Right Side) | I.D.: 32 mm |
Temperature Control | PID control |
Temperature Setting | Digital setting with ▲▼ keys |
Temperature Display | Measured temperature: 4-digit orange LED digital display + VFD fluorescent display |
Timer / Timer Resolution | 0 min. ~ 999 hrs. 59 min. / 1 min. |
Operation Function | Fixed temperature, auto stop, auto start, program (up to 32 steps, repeat operation) |
Additional Functions | Timer function (accumulated time to 49,999 hrs), calibration off-set function, clock display |
Safety Device | Self diagnostic function (Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention function), Key lock, Over current ELB, Overheat prevention device |
Internal Dimensions W X D X H | 600 x 477 x 500 mm |
External Dimensions W X D X H | 710 x 645 x 913 mm |
Internal Capacity | 143L |
Shelf Plate Load | 15kg / pc. |
Shelf Rest Step Number / Pitch | 13 steps / 30mm |
Power Supply (50/60Hz) | AC115V 9A (with plug) AC220V 5.5A (no plug, round terminal) |
Weight | ~89kg |
Shelf / Shelf Brackets | 3 pcs. / 6 pcs. stainless steel punched metal |
Door Keys | --- |
Optional Items | Stand, additional shelf, cable port (ø30/50mm), recorder, warning light combination (stand-by/operation/error), observation window, external communication function (RS485), temperature output terminal (4-20mA), external alarm output terminal, time up output terminal |