SHIPS VIA FREIGHT (charges apply)
Description
Inert ovens suitable for temperature test and heat treatment in a non-oxidizing environment, by introducing N₂ gas into the chamber
Features
Performance and functions
- Heat resistance test and heat treatment of up to 360°C
- Simple operation by interactive key input
- Standard equipped with various operation modes such as program operation and calibration offset function, power failure recovery mode selection, and user configuration information saving
- Repeatable operation function up to maximum 99 steps, 99 patterns controller with repeat function
- N₂ gas flow amount controllable
Safety features
- Enhanced safety countermeasure, including self-diagnostic functions, digital setting, independent overheat prevention device and electric leakage breaker
- In case of door opening during operation, fan and heater turn OFF by door switch
Specifications
MODEL | DN611IE |
System | Forced Convection |
Operating Temp. Range | Room Temp. +15 to 360°C |
Temp. Adjustment Accuracy | ±0.2°C (at 360°C) |
Temp. Fluctuation | ±0.6°C (at 360°C) |
Temp. Uniformity | ±3°C (at 360°C) |
Temp. Gradient | 20°C(at 360°C) |
Max. Temp. Reaching Time | ~60 min. |
Nitrogen Substitution Time Required | ~70 min. (ordinary temp with oxygen concentration of 2%) |
Interior | Stainless steel plate |
Exterior | Cold rolled steel plate with baked melamine resin coating |
Heat Insulator | Glass wool + Ceramic fiber |
Heater | SUS Pipe Heater 4.0kW |
Sensor | K thermocouple for temperature control and independent overload prevention device |
Fan Type / Motor | Sirocco Fan / Condenser Type |
Flow Meter, Gas Carrier | Max. Flow 30L/min, O.D. 9mm Hose Nipple |
Temp. Controller | PID Control by microcomputer |
Temp. Display Type | Temp. display: Digital display by 4 digit green LED (resolution:1°C) Setting temp. display: Digital display by 5 digit orange LED (resolution:1°C) |
Timer / Timer Resolution | 1min. ~ 99hrs. 59mins. or 100hrs. ~ 999hrs. / 1min. or 1hr. |
Operation Function | Fixed temp. operation, Auto-start, Auto-stop, Quick auto-stop, Program Operation |
Program Mode | Repeatable operation function up to max 99 steps or 99 patterns. |
Additional Functions | Power on and operation time integrating function (up to 65535 hours), calendar time (24 hours), calibration offset, Monitor display of integrated power consumption, total CO₂ emissions and heater operating output, power failure recovery mode, save and read out of user settings |
Heater Circuit Control | Triac with Zero-cross |
Safety Device | Self diagnostic functions (Sensor failure, SSR short circuit, Heater line disconnection, Main Relay contact damaged, Automatic overheat prevention), Key lock function, Independent overheating prevention, Electric leakage breaker, Door switch |
Internal Dimensions WxDxH | 620 x 600 x 600 mm |
External Dimensions WxDxH | 790 x 845 x 1065 mm |
Internal Capacity | 223L |
Shelf Max. Load | ~30kg / shelf |
Shelf Support Qty. / Pitch | 17pcs. / 30mm |
Power Source | Single phase 220V 19A (no plug, round terminal) |
Weight | ~130kg |
Shelf Plate / Bracket | Stainless wire, 2 pcs. / 4 pcs. |