SHIPS VIA FREIGHT (charges apply)
Description
Large scale vacuum drying oven designed for treatment of large-sized parts
Features
Performance and functions
- Vacuum pump can be installed inside the oven
- Quick connect / disconnect of vacuum pipes for easy vacuum pump maintenance
- Because the exhaust system is improved to significantly shorten the time to reach vacuum, working efficiency is improved.
- Use specialized function menu key and ▲▼ key to set. With program operation function, use submenu key to operate overheat protector, deviation correction, etc.
Safety features
- Self-diagnostic functions (abnormal temperature sensor, heater disconnection, auto overheat prevention, SSR short circuit), overheat protector, ELB to prevent overcurrent, key lock, etc.
- For safety, resin protection panel is installed at the observation window
Specifications
Method | Decompression • chamber wall heating |
Operating Temp. Range | 40~200°C |
Operating Vacuum Range | 101~0.1kPa (760~1Torr) |
Temp. Adjustment Accuracy | ±1.0°C (at 200°C) |
Interior | Stainless steel plate |
Exterior | Cold rolled steel plate with chemical proofing coating |
Insulating Material | Glass fiber |
Heating Method | Decompressed chamber wall direct heating |
Heater Power | 14.4kW |
Observation Window | Toughened glass + resin protection panel |
Vacuum Gauge | Pointer type, -100~0kPa |
Vacuum Pump Installation Room | Yes |
Temp. Control | 3 segments PID |
Temp. Setting | Use specialized function menu key and up/down key to set |
Temp. Display | Measured temp. display: green 4-digit LED digital display |
Timer | 1min-99 hr 59 min and 100 hr-999 hr 50 min (attached with timing wait function) |
Operation Function | Fixed temp. auto start, auto stop, program operation |
Program Mode | Program operation 3 segments 30 steps (30 steps×1, 15 steps×2, 10 steps×3) |
Additional Function | Deviation correction, key lock, power outage compensation |
Heater Circuit Control | SSR driving |
Sensor | K thermocouple (temp. controller and overheat protector) |
Safety Device | Self-diagnosis circuit (abnormal temp. sensing, heater disconnection, auto overheat prevention, SSR short circuit), overheat protector, EBL to prevent overcurrent, key lock, etc. |
Internal Dimensions W×D×H | 1000×1000×1000 mm |
External Dimensions W×D×H | 1300×1280×2110 mm |
Internal Capacity | 1000L |
Air Exhaust Port | NW40 flange |
Air Suction Port | Rc 3/8 |
Power Source (50/60Hz) Rated Current | 3 phase AC480V 18A (no plug, round terminal) |
Weight | ~1000kg |
Accessories | Stainless steel punching plates, 4 pcs. |
Optional | Shelf plate, vacuum pump, N₂ introduction device, recorder, alarm indicator lamp (stand-by/running/malfunction), external communication (RS485), temp. output terminal (4~20mA), Output terminal for external alarm, time up output terminal |