SHIPS VIA FREIGHT (charges apply)
Description
Performance and functions
- Bestseller based on excellent performance and affordability
- Superior temperature accuracy
- Programmable PID controller for easy program settings (30-step, 3-pattern program controller with repeat functions)
- Fixed setting, Quick Auto stop, Auto stop, Auto start, Program operating modes with easy control capabilities
- Increased safety and self-diagnostic functions
- Overheating prevention and calibration off-set are possible with auxiliary functions
- Easy to use and maintain
- Built in exhaust ports
Safety features
- Self-diagnostic functions (Temperature sensor abnormal, Heater disconnection, SSR-short), Automatic overheating prevention, Electric leakage breaker with over current protection, Key lock function
Specifications
Circulation Method | Forced air circulation |
Operating Temp. Range | Room temp. +10°C~260°C |
Temp. Adjustment Accuracy | ±1°C (at 210°C) |
Temp. Distribution Accuracy | ±2.5°C (at 210°C) |
Max. Temp. Reaching Time | 60min |
Interior/Exterior Material | Stainless steel / Cold rolled steel plate with melamine resin baking finish |
Heat Insulating Material | Glass wool |
Heater | SUS pipe heater/1.5kWx2 |
Fan Type / Fan Motor | 1pc / 30W |
Cable Hole | 30mm I.D. (on the right side) 1pc. |
Exhaust Port | 30mm I.D.×2 (the back) |
Temp. Controller | 3 patterns program controller, PID control by microprocessor |
Temp. Setting Method | Digital setting by ▲/▼ key |
Temp. Display | Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED |
Timer | 1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. with timer wait function |
Operation Function | Fixed temperature operation, Program operation, Auto start, Auto stop, Quick Auto-stop |
Program Mode | Program operation : 3 patterns, 30 steps (30 steps×1, 15 steps×2, 10 steps×3) Pattern repeat function |
Additional Functions | Calibration off-set function, Key lock, Uninterruptible power for memory |
Heater Circuit Control | SSR control |
Sensor | K-thermocouple |
Safety Device | Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Automatic overheating prevention), Key lock function, Overheat prevention, Electric leakage breaker with over current protection |
Internal Dimensions W×D×H | 600×500×1000 mm |
External Dimensions W×D×H | 710×651×1608 mm |
Internal Capacity | 300L |
Shelf Plate With Standard Load | 15kg/piece |
Shelf Rest Step Number / Shelf Rest Pitch | 29 steps / 30mm |
Power Source 50/60Hz | 220V 15A (no plug, round terminal) |
Weight | 110kg |
Shelf Plate | Stainless steel, 1pc on the bottom screwed (DKN912C, 2 pcs) |
Shelf Plate / Bracket | 4 pcs. / 8 pcs. |